Basic Info.
Appliance
Food Analysis, Medical Research, Biochemistry
Certification
RoHS, FCC, CE, ISO9001
Measure Range
0 to +-1999mv
Temperature Range
0 to 60 C
Response Time
Less Than 30s
Power Supply
Four AA Alkaline Batteries
Specification
180mm× 80mm× 30mm
Product Description
Portable ORP meter
The purpose of the Instrument:
Digital ORP meter is a high precision instrument for measuring MV value in laboratory. With MV temperature dual function, standard ORP electrode and temperature electrode, fast reaction, good stability. The instrument is suitable for industrial and mining enterprises, scientific research, agriculture, medicine, teaching, environmental protection and so on. It is used to measure the electrode potential (MV value) of water solution.
Technical parameter of instrument:
Model No. : YORP-P
Measuring range :(0~±1999)Mv
Resolution: 1mV
Temperature range: (0~60)ºC
Basic configuration: ORP electrode, [ suitable for solution temperature (5 ~ 60 °C) measurement ] battery; temperature electrode; calibration reagent
escription of instrument keyboard:
Push the button: Function
△ : "△ " key, this key is the numerical value to rise the key, press this key "△ " to adjust the numerical value to rise.
▽ : "▽ " key ,The "gradient" key, which is the numeric drop key, Press this key "gradient" to adjust the value down.
Instrument Operation Method:
a. Standard reagent mix: Add 60ML distilled water to a packet of standard reagent, dissolve and stir until ready to use 30 minutes later.
b. Instrument calibration, switch to calibration, after the electrodes are washed with distilled water and dried. Add calibration solution 256MV, stir it to make full contact, wait for reading stability, press the confirmation key, calibration is complete.
Instrumental measurement:
Switch to the measuring pad, put the electrode into the solution, stir it to make full contact, wait until the reading is stable, press the confirmation button, then the screen display value is the correct reading of the solution under test.
Usage of electrode and matters needing attention:
a. ORP ELECTRODE STORAGE: After cleaning the ELECTRODE, put it into the saturated solution of KCL.
b. ORP electrode cleaning: IF THE PLATINUM ELECTRODE is found to have dirt, Ph = 4 in the standard solution of the measurement value in excess of the standard value, should be cleaned.
Inspection and judgment of general faults:
Most measurement problems arise from faulty electrodes or faulty measuring methods, not from the instrument itself. In addition, the use of standard buffer, samples and many other factors can also lead to problems, please carefully analyze to determine the problem.
a. If the electrode judges that the main machine is normal, and when it is tested with the electrode, the indication value is unstable or the response of the instrument is very slow; the repeatability is very poor; or it can not be calibrated to the required value, please check the electrode: whether the connection is good or not, if the electrode leads are loose or broken; if the electrode bulb is immersed in the sample; if the electrode solution contains bubbles; if the electrode Bulb is contaminated; if so, replace the electrode.
b. Standard buffer if the host, electrodes are normal, incorrect readings or can not be calibrated, please check the buffer solution: whether to use the correct standard buffer; If so, reformulate the standard buffer.
FAQ
1. Who are we?
Jin Zhuang instrument focus on R&D and production of Water Quality analyzer & sensor since 2014.
þ Employees:120+ people
þ Annual growth rate: 40%
þ R&D experiences: 8+ years
þ Technical patents: 50+
þ Annual production quantities: 180,000pcs
þ Cooperation: SGS, VOLKSWAGEN, NONGFU SPRING, ENENMAE, 999, ZHEJIANG UNIVERSITY,
NANJING UNIVERSITY, SHANGHAI JIAOTONG UNIVERSITY,FUDAN UNIVERSITY,WUHUAN UNIVERSITY.
þ Main Industries: Drinking water, Power plant, Water treatment plant, Pharmaceutical, Fish farming, Swimming pool, university, hospital, food industry etc.
2. How can we guarantee quality?
1) 100% QC for all of products before shipping
2)Testing pictures and videos to be provided before shipping
3) 1 year warranty for the analyzer
4) IS9001, CE, SGS and other products patent certifications
3.What's our main business?
Whole solution for water quality instruments. Including analyzers and sensors for pH, COD, BOD,Ammonia Nitrogen,Total Phosphorus , Total Nitrogen , Color,
Portable Microbial Detector, Infrared Oil Tester, conductivity, Dissolved Oxygen, Turbidity, TSS, Residual Chlorine, Nitrate, Hardness and etc.
4. Why choose us instead of other suppliers?
1) Jin Zhuang established since 2014, top supplier of water quality instrument.
2)One stop solution provider for water quality monitoring, thousands of projects reference.
3)24 hours after-sales service team, products training on time.
4)15 + years R&D experience, support OEM & ODM service.
5)30+ Patents for water quality analyzer and sensor
5. What service can we provide?
Incoterms: EXW,FOB, CFR, CIF, FAS, CIP, FCA, CPT, DEQ, DDP, DDU,
Payment Currency: USD, EUR, JPY, CAD, AUD, HKD, GBP, CNY,CHF;
Payment method: T/T, X Transfer, Money Gram, Credit Card, PayPal,Western Union, Cash, Escrow;
Language: German,English, Chinese, Spanish, Korean
Address:
No. 52 a Building, Jinliang Road, Zhuqiao Town, Pudong District, Shanghai, China
Business Type:
Manufacturer/Factory
Business Range:
Chemicals, Industrial Equipment & Components, Instruments & Meters
Management System Certification:
ISO 9001
Company Introduction:
Jin Zhuang is a high-tech enterprise founded in 2014, it has been Committed to the R & D, production, sales and service, during 8 Years the products related to hundreds of water quality analysis Instruments. The Technology involves computer, single-chip Microcomputer software and hardware, optics, chemical analysis And other technical fields.
• In 2016, the first portable microbial and bacterial detector in China was Developed jointly with Professor Zhou′s team from the nano Research Institute of Suzhou China Academy of Sciences, and a national patent Was applied.
• Products include: COD Analyzer, Ammonia Analyzer, Total Phosphorus analyzer, Total nitrogen analyzer and other different Kinds of Water quality heavy metal. Inorganic salt, Organic Compound, turbidity, TSS, infrared oil tester, COD standard Digester of national standard method, multi (single) parameter Heavy metal tester, microbial tester, and expandable UV / visible Multi (single) parameter water quality analyzer.